3 hours
Ice packs
1.15 ng/mL
cell, normal
Colorimetric
3.12-200 ng/mL
6-11 Business days
Double-antibody Sandwich
Sus scrofa; Porcine (Pig)
Short term: 4°C; Long term: see manual.
Serum, Plasma and other biological fluids.
For research use only. Not for diagnostic procedures.
Cytokine, Tumor immunity, Infection immunity, Immune molecule
ELISA Enzyme-linked immunosorbent assays Code 90320007 SNOMED
Regulated On Activation In Normal T-Cell Expressed And Secreted
The Stop Solution is acidic. Do not allow to contact skin or eyes.
For cells, cell lines and tissues in culture till half confluency.
The kit is manufactured at ISO 9001 and ISO 13485 certified facilities.
Pigs and the smaller guinea pigs are frequent used as models for humans.
Use Pig Regulated On Activation In Normal T-Cell Expressed And Secreted (RANTES) ELISA Kit before 8 months
E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays
This assay has high sensitivity and excellent specificity for detection of Regulated On Activation In Normal T-Cell Expressed And Secreted
No significant cross-reactivity or interference between Regulated On Activation In Normal T-Cell Expressed And Secreted and analogues was observed.
No significant cross-reactivity or interference between Regulated On Activation In Normal T-Cell Expressed And Secreted and analogues was observed.
CCL5, SCYA5, SISd, EoCP, Chemokine C-C-Motif Ligand 5, Eosinophil Chemotactic Cytokine, T-cell Specific Protein p288, Small Inducible Cytokine Subfamily A (Cys-Cys)Member 5
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Regulated On Activation In Normal T-Cell Expressed And Secreted were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Regulated On Activation In Normal T-Cell Expressed And Secreted were tested on 3 different plates, 8 replicates in each plate.CV (%) = SD/meanX100;Intra-Assay: CV
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.