3 hours
6.1 pg/mL
Ice packs
Colorimetric
cell, normal
15.6-1000 pg/mL
Rattus norvegicus
6-11 Business days
Rattus norvegicus (Rat)
Double-antibody Sandwich
Short term: 4°C; Long term: see manual.
For research use only. Not for diagnostic procedures.
ELISA Enzyme-linked immunosorbent assays Code 90320007 SNOMED
Cytokine, Tumor immunity, Infection immunity, Immune molecule
Regulated On Activation In Normal T-Cell Expressed And Secreted
For cells, cell lines and tissues in culture till half confluency.
The Stop Solution is acidic. Do not allow to contact skin or eyes.
The kit is manufactured at ISO 9001 and ISO 13485 certified facilities.
Serum, Plasma, Tissue homogenates, Cell lysates, Cell culture supernates and other biological fluids
Use Rat Regulated On Activation In Normal T-Cell Expressed And Secreted (RANTES) ELISA Kit before 8 months
E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays
This assay has high sensitivity and excellent specificity for detection of Regulated On Activation In Normal T-Cell Expressed And Secreted
No significant cross-reactivity or interference between Regulated On Activation In Normal T-Cell Expressed And Secreted and analogues was observed.
No significant cross-reactivity or interference between Regulated On Activation In Normal T-Cell Expressed And Secreted and analogues was observed.
CCL5, SCYA5, SISd, EoCP, Chemokine C-C-Motif Ligand 5, Eosinophil Chemotactic Cytokine, T-cell Specific Protein p288, Small Inducible Cytokine Subfamily A (Cys-Cys)Member 5
Rats are used to make rat monoclonal anti mouse antibodies. There are less rat- than mouse clones however. Rats genes from rodents of the genus Rattus norvegicus are often studied in vivo as a model of human genes in Sprague-Dawley or Wistar rats.
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Regulated On Activation In Normal T-Cell Expressed And Secreted were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Regulated On Activation In Normal T-Cell Expressed And Secreted were tested on 3 different plates, 8 replicates in each plate.CV (%) = SD/meanX100;Intra-Assay: CV
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.