3 hours
Ice packs
0.055 ng/mL
Colorimetric
0.156-10 ng/mL
6-11 Business days
bone, cell, marrow
Homo sapiens (Human)
Double-antibody Sandwich
CD317, Tetherin, HM1.24 antigen
Bone Marrow Stromal Cell Antigen 2
Short term: 4°C; Long term: see manual.
CD & Adhesion molecule, Infection immunity
For research use only. Not for diagnostic procedures.
Tissue homogenates, Cell lysates and other biological fluids
ELISA Enzyme-linked immunosorbent assays Code 90320007 SNOMED
The Stop Solution is acidic. Do not allow to contact skin or eyes.
The kit is manufactured at ISO 9001 and ISO 13485 certified facilities.
Use Human Bone Marrow Stromal Cell Antigen 2 (BST2) ELISA Kit before 8 months
This assay has high sensitivity and excellent specificity for detection of Bone Marrow Stromal Cell Antigen 2
No significant cross-reactivity or interference between Bone Marrow Stromal Cell Antigen 2 and analogues was observed.
No significant cross-reactivity or interference between Bone Marrow Stromal Cell Antigen 2 and analogues was observed.
Antigens are peptides or recombinant or native dependent on the production method.For cells, cell lines and tissues in culture till half confluency.
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Bone Marrow Stromal Cell Antigen 2 were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Bone Marrow Stromal Cell Antigen 2 were tested on 3 different plates, 8 replicates in each plate.CV (%) = SD/meanX100;Intra-Assay: CV
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,Human proteins, cDNA and human recombinants are used in human reactive ELISA kits and to produce anti-human mono and polyclonal antibodies. Modern humans (Homo sapiens, primarily ssp. Homo sapiens sapiens). Depending on the epitopes used human ELISA kits can be cross reactive to many other species. Mainly analyzed are human serum, plasma, urine, saliva, human cell culture supernatants and biological samples.