cell
3 hours
leukemia
Ice packs
0.127 ng/mL
Colorimetric
0.312-20 ng/mL
Tumor immunity
6-11 Business days
Homo sapiens (Human)
Double-antibody Sandwich
Short term: 4°C; Long term: see manual.
Myeloid Cell Leukemia Sequence 1, Bcl2 Related
For research use only. Not for diagnostic procedures.
Tissue homogenates, Cell lysates and other biological fluids
ELISA Enzyme-linked immunosorbent assays Code 90320007 SNOMED
The Stop Solution is acidic. Do not allow to contact skin or eyes.
For cells, cell lines and tissues in culture till half confluency.
The kit is manufactured at ISO 9001 and ISO 13485 certified facilities.
Use Human Myeloid Cell Leukemia Sequence 1, Bcl2 Related (MCL1) ELISA Kit before 8 months
This assay has high sensitivity and excellent specificity for detection of Myeloid Cell Leukemia Sequence 1, Bcl2 Related
No significant cross-reactivity or interference between Myeloid Cell Leukemia Sequence 1, Bcl2 Related and analogues was observed.
No significant cross-reactivity or interference between Myeloid Cell Leukemia Sequence 1, Bcl2 Related and analogues was observed.
EAT, MCL1L, MCL1S, BCL2L3, TM, Induced Myeloid Leukemia Cell Differentiation Protein Mcl-1, Bcl-2-like protein 3, Bcl-2-related protein EAT/mcl1, mcl1/EAT
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Myeloid Cell Leukemia Sequence 1, Bcl2 Related were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Myeloid Cell Leukemia Sequence 1, Bcl2 Related were tested on 3 different plates, 8 replicates in each plate.CV (%) = SD/meanX100;Intra-Assay: CV
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,Human proteins, cDNA and human recombinants are used in human reactive ELISA kits and to produce anti-human mono and polyclonal antibodies. Modern humans (Homo sapiens, primarily ssp. Homo sapiens sapiens). Depending on the epitopes used human ELISA kits can be cross reactive to many other species. Mainly analyzed are human serum, plasma, urine, saliva, human cell culture supernatants and biological samples.