cell
Ice packs
11.5 pg/mL
27.4-20000 pg/mL
Chemiluminescent
6-11 Business days
2 hours, 40minutes
Homo sapiens (Human)
Double-antibody Sandwich
Programmed Cell Death Protein 1 Ligand 1
Short term: 4°C; Long term: see manual.
For research use only. Not for diagnostic procedures.
Serum, Plasma, Tissue homogenates and other biological fluids
ELISA Enzyme-linked immunosorbent assays Code 90320007 SNOMED
The Stop Solution is acidic. Do not allow to contact skin or eyes.
The kit is manufactured at ISO 9001 and ISO 13485 certified facilities.
CD274, PDCD1LG1, B7-H, B7H1, PD-L1, PDCD1L1, PDCD1-LG1, Programed Death Ligand 1
Signal transduction, Tumor immunity, Infection immunity, Immune molecule, Autoimmunity
Use Human Programmed Cell Death Protein 1 Ligand 1 (PDL1) ELISA Kit (CLIA) before 8 months
This assay has high sensitivity and excellent specificity for detection of Programmed Cell Death Protein 1 Ligand 1
No significant cross-reactivity or interference between Programmed Cell Death Protein 1 Ligand 1 and analogues was observed.
No significant cross-reactivity or interference between Programmed Cell Death Protein 1 Ligand 1 and analogues was observed.
For cells, cell lines and tissues in culture till half confluency.FAS ligand and other ligands are binding to the receptor for signaling pathways for example in apoptosis or JNK signaling. Receptor agonists are often tested for drug development.
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Programmed Cell Death Protein 1 Ligand 1 were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Programmed Cell Death Protein 1 Ligand 1 were tested on 3 different plates, 8 replicates in each plate.CV (%) = SD/meanX100;Intra-Assay: CV
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,Human proteins, cDNA and human recombinants are used in human reactive ELISA kits and to produce anti-human mono and polyclonal antibodies. Modern humans (Homo sapiens, primarily ssp. Homo sapiens sapiens). Depending on the epitopes used human ELISA kits can be cross reactive to many other species. Mainly analyzed are human serum, plasma, urine, saliva, human cell culture supernatants and biological samples.